FALL PROTECTION CHECKLIST

 

Fall Protection Checklist

Download link given in the bottom

Project:

Project Location:

Fall Protection Locations:

Supervisor:

Date:

Time:

þ

Step

Action

Description

q

1.

Choose appropriate fall protection system

Consider the work to be performed, the training needed for each system, the project conditions and the availability.

q Powered Elevating Work Platform

Perform system checks, ensure level ground, operate according to manufacturers’ recommendations, tie off to PEWP or to adequate anchor point above at all times.

q Horizontal Lifeline

Install and use according to engineer’s design drawings, use min. ½” steel wire, <30 ft. between vertical posts, <15” sag in a 30 ft. span, 3 clips tying wire at beam end, engineer’s design drawings available, workers using double lanyard, and workers tied off at all times.

q Vertical Lifeline

Column adequately secured with ½” steel wire or 5/8”

polypropylene rope, vertical lifeline attached, vertical lifeline with rope grab extends from top of column to base, 1 worker using lifeline at a time.

q Self-Retracting Lifeline (SRL)

Anchor to approved roof anchor, 1 worker using SRL at a time, must be moved periodically, lifeline locks up in quick movement, automatically retracts when tension removed, minimizing fall distance.

q Guardrail, Scaffolding, etc.

Removes fall potential by providing a physical barrier, must meet minimum horizontal and vertical forces, must have top rail, midrail and toe board, scaffolding must be built accordingly.

q

2.

Frequent inspections of fall protection components

All components of fall protection systems are to be inspected prior to each use by each worker. If deficiency is found, remove equipment from service.

q Harness

Burns, cuts, loose stitching, frayed webbing, D-rings, grommets and buckles not worn or damaged, CSA stamp.

q Lifelines

Burns, cuts, frayed material, no discoloration or other damage.

q Lanyards

Burns, cuts, loose stitching, frayed webbing, CSA stamp, shock absorber in good condition, locking snap hook.

q Anchor Points

Able to support 3600 lbs., verified by a competent worker.

q PEWP

Maintenance log, manufacturer’s recommended inspections.

q Rope Grab

Damage, cracking, dents, bends, connecting rings centered, rust, moving parts working smoothly, other wear.

q

3.

Rescue procedure

chosen

Refer to Construction Regulations, Sec. 26 for employer’s Fall Rescue requirements.

q

4.

Engineer’s design

drawings and

manufacturer's

specifications available

Engineer’s design drawings for:

q Horizontal lifeline   q Scaffold system   q Anchor systems

Manufacturer's specifications for:

q Anchor systems  q PEWP  q SRLs  q Harnesses  q Rope grab